FIRE ALARM CONTROL PANEL (CONVENTIONAL)
>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Ancillary connections for repeaters & other system add-on including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
>> Multilingual variants (subject to quantities). >> Space for 2 x 12V 7Ah VRLA batteries.

MODEL NO: PNC-1004-2Z, PNC-1004-4Z,PNC-1004-6Z,PNC-1004-8Z, PNC-1004-10Z,PNC-1004-12Z, PNC-1004-14Z, PNC-1004-16Z, PNC-1004-18Z
POWER SUPLY: AC165-260V.
LOOP NO. (2-18) ZONE

FIRE ALARM CONTROL PANEL (CONVENTIONAL)

>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Ancillary connections for repeaters & other system add-on including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc).
>> Multilingual variants (subject to quantities).
>> Space for 2 x 12V 7Ah VRLA batteries.

POWER SUPLY: AC165-260V
MODEL NO: PNC-1004-2Z/ PNC-1004-4Z/ PNC-1004-6Z/ PNC-1004-8Z,
LOOP NO. (2,4,6,8) ZONE

FIRE ALARM CONTROL PANEL (CONVENTIONAL)

>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Multilingual variants (subject to quantities).
>> Space for 2 x 12V 7Ah VRLA batteries.

POWER SUPLY: AC165-260V
MODEL NO: PNC-1104-2Z/ PNC-1104-4Z/ PNC-1104-6Z/ PNC-1104-8Z/PNC-1104-10Z/PNC-1104-12Z/PNC-1104-14Z/PNC-1104-16Z/PNC-1104-18Z
LOOP NO. (2-18) ZONE

FIRE ALARM CONTROL PANEL (CONVENTIONAL)

>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Space for 2 x 12V 7Ah VRLA batteries

POWER SUPLY: AC165-260V
MODEL NO: PNC-1100-4Z/ PNC-1100-8Z/ PNC-1104-16Z
LOOP NO. (4,8, 16) ZONE

FIRE ALARM CONTROL PANEL (CONVENTIONAL)

>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Space for 2 x 12V 7Ah VRLA batteries.

POWER SUPLY: AC165-260V
MODEL NO: PNC-1000-18Z/ PNC-1000-16Z/ PNC-1000-12Z
LOOP NO. (12,16,18) ZONE

FIRE ALARM CONTROL PANEL Wire less (CONVENTIONAL)
>> Non-latching class change sounder output, latching fire & non-latching fault outputs (via expansion loom).
>> Short circuit=fire facility (pre-1980 BS, no resistors in call points, selectable on a zone by zone basis).
>> Space for 2 x 12V 7Ah VRLA batteries.

POWER SUPLY: AC165-260V
MODEL NO: PNC-1500-2Z/ PNC-1500-4Z/ PNC-1500-6Z/PNC-1500-8Z
LOOP NO. (2,4,6,8) ZON